Rémy Oudompheng authored
The linker accepts MOVB involving non-byte-addressable registers, by generating XCHG instructions to AX or BX. It does not handle the case where nor AX nor BX are available. See also revision 1470920a2804. Assembling TEXT ·Truc(SB),7,$0 MOVB BP, (BX)(AX*1) RET gives before: 08048c60 <main.Truc>: 8048c60: 87 dd xchg %ebx,%ebp 8048c62: 88 1c 03 mov %bl,(%ebx,%eax,1) 8048c65: 87 dd xchg %ebx,%ebp 8048c67: c3 ret and after: 08048c60 <main.Truc>: 8048c60: 87 cd xchg %ecx,%ebp 8048c62: 88 0c 03 mov %cl,(%ebx,%eax,1) 8048c65: 87 cd xchg %ecx,%ebp 8048c67: c3 ret R=golang-dev, rsc CC=golang-dev https://golang.org/cl/7226066