Roger Peppe authored
It's accessed without mutex protection in a different goroutine from the one that sets it. Also make sure that Client.Call after Client.Close will reliably return ErrShutdown, and that clients see ErrShutdown rather than io.EOF when appropriate. Suggestions welcome for a way to reliably test the mutex issue. R=r, iant CC=golang-dev https://golang.org/cl/7338045
7edd1335